1)Gases Pollutants in Ambient Air quality : |
2) Organic Pollutants in SPM: |
3)Inorganic Pollutants in SPM: |
Parameters |
Benzene soluble organics by weight |
Toxic Metals |
Test |
SO2 |
As |
Fluoride |
NO x |
BHC |
Cd |
SO4 |
H 2S |
Aldrine |
Zn |
NO3 |
NH3 |
Endrene |
Mn |
Cl2 |
HC |
Benzoapyrene, |
Pb |
PO4 |
CO |
|
Cu |
Ammonia V |
CO2 |
|
Mg |
|
O 2 |
|
|
|
|
| |
|
| |
Particulate size studies : We can provide the particulate size analysis by using the technique of Electron Microscopy. The Electron Micrograph will show the size of particulate at angstrom/micron level. The results can be given in photographic form. Average size distribution of particles can also be studied. The results will be given in graphical form. |
| |
| II. Respirable particulate sampling, by using respirable particulate sampler, for estimation of total SPM, respirable SPM (< 10 micron size), free silica, lead etc. |
| |
| i) |
Total SPM ( greater than 10 microns ) |
| ii) |
Respirable particulate ( less than 10 microns ) |
| iii) |
Free silica, lead in respirable particulate fraction. |
|
| |
| III. Micrometeorological data like wind speed, direction, relative humidity, temperature (maximum and minimum) etc. Dust fall measurements etc. Installation of site metrological lab. |
| |
| IV. After recording site-specific met data, stack emission predicated modeling can also be taken up using ISCST3, 5, (to determine short and long term impacts) standard software accepted and followed by MoEF New Delhi. Modeling using ISCST / CPCB approved software for determining dispersion of air pollutants around the periphery of the plant / Mine. |
| |
| V. Stack monitoring: As per standard APHA / CPCB methods ; monitored parameters Temp., Flow, Volume, SPM, SO2, NOx, HC, CO |
| |
| |
1 |
NOx |
8 |
SPM |
2 |
SO2 |
9 |
NO2 |
3 |
CO |
10 |
NH3 |
4 |
Velocity |
11 |
Flow |
5 |
SO3 |
12 |
Total Fluoride |
6 |
Particulate Fluoride |
13 |
Gaseous Fluoride |
7 |
Particulate Analysis & heavy metal estimation |
|
|
|
| |
1 |
Wind Speed |
1 |
Carbon Monoxide |
2 |
Wind Direction |
2 |
Oxides of Nitrogen |
3 |
Temperature |
3 |
Hydrogen |
|
| |
|
| |
1 |
SPM |
APHA (Second Edition) |
HVS |
1 µg/m3 |
2 |
RPM |
APHA (Second Edition |
Respirable dust Sampler |
1 µg/m3 |
3 |
SO2 |
Improved West & Geake |
HVS ( through glass impinges |
0.02 µg/m3 |
4 |
NOx |
Jacob & Hochheiser |
HVS ( through glass impinges |
0.02 µg/m3 |
5 |
CO |
Instrumental |
CO Analyser |
100 µg/m3 |
6 |
Total Fluoride |
APHA (Second Edition) |
HVS |
0.1 µg/m3 |
7 |
Particulate Fluoride |
APHA (Second Edition) |
HVS |
0.1 µg/m3 |
8 |
Gaseous Fluoride |
APHA (Second Edition) Spectrophotometeric |
HVS (through glass impinges) |
0 -1.4 µg/ml |
9 |
NH3 |
APHA (Second Edition) |
HVS (through glass impinges) |
0.01µg/25ml |
10 |
Heavy metals in SPM/RPM |
APHA – Instrumental
Thermo ICP – 6300 with Hydride generator, Calibration stds. Used E Merck – Germany, NIST Certified |
Specian sampler, Samples collected by NEERI, Nagpur for PM 10, 2.5 ; sampling location Delhi |
Detection limits – list of elements enclosed |
|
| |
|
| |
1 |
Inductively coupled plasma emission Spectrometer |
1 |
Thermo electron UK
Model - iCAP 6300 |
2 |
Gas Liquid Chromatograph |
1 |
Ashco |
3. |
Specific Ion Meter |
1 |
Thermo Orion – CN, F |
4. |
Reverse Osmosis plant |
1 |
Centron Engineering |
5. |
Micro Analytical Balance |
2 |
Mettler Toledo, Ohaus |
|
| |
|
| |
High Volume Sampler – 6 Nos. |
Aero Vironment Engineer’s Inc. Nagpur |
SPM - 0.5 ug/m3 onwards
SO2 - 5 ug/m3 onwards
NOx - 5 ug/m3 onwards |
0.5 ug/m3
5 ug/m3
5 ug/m3 |
Respirable Dust Sampler –3 Nos |
Aero Vironment Engineer’s Inc.Nagpur |
0. 5 ug/m3 |
0. 5 ug/m3 |
Gas Analyser - 1 No.
CO, CO2, HC, O2 |
Endee Engineers
Mumbai |
CO - 0 to 4000 ppm
HC - 0 to 100 %
O2 - 0 to 25 %
CO - 0 to 25 % |
1 ppm
0.01 %
0.1 %
0.1 % |
|
| |
|
| |
Wind speed meter |
Orion USA |
Minimum zero and more |
- |
Wind direction |
Orion USA |
All directions |
- |
|
| |
|
| |
Stack Monitoring Kit – 3 Nos. |
Aero Vironment Engineer’s Inc.Nagpur |
SPM |
0.5 mg/M3 |
SO2 - 3.4 mg onwards |
3.4 mg/M3 |
NOx - 0.04 ug onwards |
0.04 ug/M3 |
|
| |
|
| |
Gas Analyser - 1 No.
CO, CO2, HC, O2 |
Endee Engineers
Mumbai |
CO - 0 to 4000 ppm
HC - 0 to 100 %
O2 - 0 to 25 %
CO - 0 to 25 % |
1 ppm
0.01 %
0.1 %
0.1 % |
|
| |
|